Description
Spesifikasi :
- Power Source : 20 – 33 V DC, removable terminal block (4 pins)
- Power Consumption : 29 W (frame only) at 33 V DC input, 95 W (RS Link: 2 A output) at 33 V DC input
- Indicators : POWER (green) …1, RUN (green) …1, EMERGENCY (red) …1, CPU OFF (red) …1, LAN A (green) …1, LAN B (green) …1, RS LINK A (green) …1, RS LINK B (green) …1
FAULT STATUS (yellow)
GENERAL …1, UNIT …1, NETWORK …1, EMG MIC …1, FUSE …1, POWER …1, CPU …1, ZONE …16
AMPLIFIER
PEAK (red) …2, SIGNAL (green) …2, OPERATE (green) …2, POWER (green) …2 - Operation : Fault Control Switch …2 (ACK/RESET)
Test Switch …1 (LAMP TEST)
Setting Switch: ID NUMBER, RESET, IMPEDANCE, Setting (internal front panel) - LAN A, B : Number of Connectors: 2 (LAN A, LAN B)
Network I/F: 100BASE-TX
Network Protocol: TCP, UDP, ARP, ICMP, RTP, IGMP, FTP, HTTP
Spanning tree Protocol: RSTP
Audio Transmission System: TOA Packet Audio (*1)
Audio Encoding Method: PCM
Audio Sampling Frequency: 48 kHz
Audio Quantifying Bit Number: 16 bits
Connection Device: VX-3004F, VX-3008F, Other VX-3016F, NX-300, VX-3000PM, VX-3000CT, Switching HUB
Connector: RJ45 connector
Connection Cable: Category 5 twisted pair cable (CAT5)
Number of Stages of Cascade connection: UP to 7
Maximum Cable Distance: 100 m (328.08 ft) - RS Link A, B : Number of Connectors: 2 (RS LINK A, RS LINK B)
Audio input level: 0 dB (*2)
Power feed: Max. 1 A per connector
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP)
Maximum Cable Distance: 1200 m (3937.01 ft) - DS Link : Connection Device: DS LINK of Power supply units
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP)
Maximum Cable Distance: 5 m (16.4 ft) - Analog Link : Number of Connectors: 1 input, 1 output
Connection Device: VX-3004F, VX-3008F, Other VX-3016F
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP)
Maximum Cable Distance: 800 m (2624.67 ft) - Control Input 1, 2 : 16 inputs, no-voltage make contact input, open voltage: 24 V DC, short-circuit current: 2 mA
Fault Detection System: Short circuit, Open circuit, Method: Voltage detect
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) - Emergency Control IN : Input 2: Isolated voltage input, -24 to +24 V
Connector: RJ45 connector
Connection Cable: Category 5 twisted pair cable (CAT5) - VOX Function : Threshold: -60 to 0 dB (1 dB steps)
Hysteresis: 0 to +10 dB, Hold time: 10 ms – 10 s
Settable for each audio input - Control Output 1, 2 : General outputs : 8 with CONTROL OUTPUT 1
Exclusive outputs : 3 with CONTROL OUTPUT 2 GENERAL FAULT, CPU FAULT, CPU OFF
No-voltage make contact, electrical contact output, control current: 10 mA, withstand voltage: 28 V DC
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) - ATT/Control Output : 16 outputs, no-voltage make contact, relay contact (NC, NO, C), control current: 2 mA to 5 A, withstand voltage: 125 V AC, 40 V DC | Connector: Removable terminal block (12 pins) …4
- Audio Input 1, 2, 3, 4 : 4 inputs
Sensitivity:
LINE: -20 dB (*2), MIC: -60 dB (*2)
LINE/MIC/ANC Sensor (changeable with setting software)
Gain Control: volume adjustable with volume control (internal front panel) – ∞ to 0 dB
Input Impedance: 47 kΩ, electronically-balanced
Frequency Response: 40 Hz – 20 kHz ±1 dB (at DA CONTROL LINK, 0 dB output)
Distortion: 1% or less (at DA CONTROL LINK, 0 dB output, 1 kHz)
Signal to Noise Ratio: 60 dB or more (at DA CONTROL LINK, A-weighted)
Phantom Power Supply: 24 V DC, can be set with setting software
Connector: Removable terminal block (6 pins) …2







Reviews